1. IML Error Message
Express5800/R120h-1M, R120h-2M Maintenance Guide
209
Chapter 3 Appendix
Class
Error
code
Error message
Action
Power
3F
Smart Storage Battery did not charge at
the expected rate, indicating a faulty
battery (Battery %1, service information:
0x03)
Contact your sales representative.
Power
40
Smart Storage Battery disabled due to high
ambient temperature, will be re-enabled
when temp is lowered (Battery %1, service
information: 0x04)
Contact your sales representative.
Power
41
Smart Storage Battery discharged to below
minimum voltage, resulting in the inability
of the battery to recharge properly
(Battery %1, service information: 0x05)
Contact your sales representative.
Power
42
Smart Storage Battery has exceeded the
maximum amount of devices supported
(Battery %1, service information: 0x07)
Contact your sales representative.
Power
43
Smart Storage Battery failure (Battery %1)
Contact your sales representative.
Power
44
%1 Storage Enclosure Power Supply
Failure (Power Supply %2, Box %3, %4)
Contact your sales representative.
Power
52
System Power Supply: %1 (Power
Supply %2)
Contact your sales representative.
Power
53
Power redundancy loss warning: server
power: %1W exceeded the redundant
power threshold: %2W
Contact your sales representative.
Power
54
System Power Supply: %1 (Power
Supply %2)
Contact your sales representative.
Power
55
Battery Backup Unit: %1 (Power
Supply %2)
Contact your sales representative.
(5) The list of messages about the rack infrastructure
Class
Error
code
Error message
Action
Rack
Infrastructure
1B
%1 Inadequate Power To Power On: %2
(Enclosure Serial Number %3, Slot %4)
Contact your sales representative.
Rack
Infrastructure
1C
%1 Inadequate Power To Power On: %2
(Enclosure Address %3, Slot %4)
Action is not necessary.
Rack
Infrastructure
1D
%1 Rack Name Changed (Enclosure
Serial Number %2)
Action is not necessary.
Rack
Infrastructure
1E
%1 Rack Name Changed (Enclosure
Address %2)
Action is not necessary.
Rack
Infrastructure
1F
%1 Name Changed (Enclosure Serial
Number %2)
Action is not necessary.
Rack
Infrastructure
20
%1 Name Changed (Enclosure
Address %2)
Action is not necessary.