1. IML Error Message
Express5800/R120h-1M, R120h-2M Maintenance Guide
184
Chapter 3 Appendix
Class
Error code
Error message
Action
UEFI
321
%1 Dual microSD Device Unsupported
Configuration - A microSD card is not
installed in Slot %2
Make sure whether the corresponding microSD
card is correctly mounted. If the problem persists,
contact your sales representative.
UEFI
322
%1 Dual microSD Device Unsupported
Configuration - No microSD cards are
installed.
Make sure whether the corresponding microSD
card is correctly mounted. If the problem persists,
contact your sales representative.
UEFI
323
%1 Dual microSD Device Error - The
microSD card in Slot %2 has failed.
Contact your sales representative.
UEFI
324
%1 Dual microSD Device Error - Both
microSD cards have failed.
Contact your sales representative.
UEFI
325
%1 Dual microSD Device Error -
microSD cards have conflicting
metadata. Configuration required.
Use the system utility to set up the primary
microSD card. If the problem persists, contact your
sales representative.
UEFI
326
%1 Dual microSD Device Error - The
microSD card in Slot %2 has failed. A
microSD card is not installed in Slot %3.
Contact your sales representative.
UEFI
327
AMP Configuration Error - An installed
processor does NOT support the
configured AMP Mode. System will
operate in Advanced ECC Mode.
Contact your sales representative.
UEFI
328
Power Management Controller
Firmware Error - The firmware is in
Recovery Mode.
Update the firmware of the power management
controller. If the problem persists, contact your
sales representative.
UEFI
329
Power Management Controller FW
Error - Unable to communicate with the
FW.
Please take actions in the following order.
1. Turn off the unit, disconnect the power cord,
wait 30 seconds, and then restart it.
2. If the problem persists, contact your sales
representative.
UEFI
333
%1 RESTful API Error - Unable to
communicate with iLO FW. BIOS
configuration resources may not be
up-to-date.
Please take actions in the following order.
1. Reset the iLO following the procedure of
Chapter
1 (7. Resetting and Clearing the Server)
in this
manual. Also, restart the unit.
2. If the problem persists, turn off the power of the
unit, disconnect the power cord, wait 30 seconds,
and then restart it.
3. If the problem persists, contact your sales
representative.