1. IML Error Message
Express5800/R120h-1M, R120h-2M Maintenance Guide
180
Chapter 3 Appendix
(2) The list on the messages related to processor, UPI bus, and PCIe bus
Class
Error
code
Error message
Action
CPU
3
Uncorrectable Machine Check Exception
(Processor %2, APIC ID 0x%3, Bank
0x%4, Status 0x%5'%6, Address
0x%7'%8, Misc 0x%9'%10).
Contact your sales representative.
Host Bus
3
Uncorrectable UPI Error was detected on
Processor %1
Contact your sales representative.
PCI Bus
2
Uncorrectable PCI Express Error Detected.
Slot %1 (Segment %2, Bus %3,
Device %4, Function %5). Uncorrectable
Error Status: %6
Contact your sales representative.
PCI Bus
3
Uncorrectable PCI Express Error Detected.
Embedded %1 (Segment %2, Bus %3,
Device %4, Function %5). Uncorrectable
Error Status: %6
Contact your sales representative.
PCI Bus
4
Uncorrectable PCI Express Error Detected.
Slot %1 (Segment %2, Bus %3,
Device %4, Function %5).
Contact your sales representative.
(3) The list on the messages related to POST
Class
Error code
Error message
Action
UEFI
101
Option ROM Error. An option ROM for a
PCIe device is invalid.
Contact your sales representative.
UEFI
104
ASR Timer Failure
Contact your sales representative.
UEFI
121
A Critical Error occurred prior to this
power-up.
Contact your sales representative.
UEFI
218
DIMM Initialization Error - All DIMMs
are mapped out due to memory errors
except for one to allow the system to
boot. Additional errors may be present
on the remaining DIMM. System is
booting in a degraded state.
Contact your sales representative.
UEFI
224
Power Fault Detected - FlexLOM %1
Turn off the power on the unit, disconnect the
power cord, and check the installation of
FlexLOM %1. Wait 30 seconds, and then restart it.
If the problem persists, contact your sales
representative.
UEFI
225
Power Fault Detected-Mezzanine %1.
Turn off the power on the unit, disconnect the
power cord, and check the installation of
mezzanine %1. Wait 30 seconds, and then restart
it. If the problem persists, contact your sales
representative.