1. IML Error Message
Express5800/R120h-1M, R120h-2M Maintenance Guide
188
Chapter 3 Appendix
Class
Error code
Error message
Action
UEFI
371
IMPORTANT: Processor %1, DIMM %2.
New NVDIMM detected and has been
disabled.
Sanitize the NVDIMM connected to the
corresponding processor. If the problem persists,
contact your sales representative.
UEFI
372
IMPORTANT: Processor %1, DIMM %2.
New NVDIMM detected and has been
disabled.
Sanitize the NVDIMM connected to the
corresponding processor. If the problem persists,
contact your sales representative.
UEFI
373
IMPORTANT: NVDIMM(s) have been
removed from Processor %1. All
NVDIMMs on Processor %2 have been
disabled.
Please take actions in following order.
1. Sanitize the NVDIMM connected to the
corresponding processor.
2. If the problem persists, contact your sales
representative.
UEFI
374
NVDIMM Error - Processor %1,
DIMM %2 (SN:%3-%4-%5-%6)
received a memory initialization or
uncorrectable error. All NVDIMMs on
Proc %7 are disabled. Data on NVDIMM
may have been lost
Please take actions in following order.
1. Sanitize the NVDIMM.
2. Contact your sales representative.
UEFI
375
NVDIMM Error - Processor %1,
DIMM %2 (SN:%3-%4-%5-%6)
received a memory initialization or
uncorrectable error. All NVDIMMs on
Proc %7 are disabled. Data on NVDIMM
may have been lost.
Please take actions in following order.
1. Sanitize the NVDIMM.
2. Contact your sales representative.
UEFI
376
NVDIMM Error - Processor %1,
DIMM %2. NVDIMM set for interleaving
disabled but system configured for
interleaving enabled. All NVDIMMs on
Processor %3 are disabled.
Set
NVDIMM Interleaving
to
Disabled
, or
sanitize the NVDIMM. If the problem persists,
contact your sales representative.
UEFI
377
NVDIMM Error - Processor %1,
DIMM %2. NVDIMM set for interleaving
enabled but system configured for
interleaving disabled. NVDIMM has
been disabled.
Set
NVDIMM Interleaving
to
Enabled
, or sanitize
the NVDIMM. If the problem persists, contact your
sales representative.
UEFI
378
NVDIMM Error - Processor %1,
DIMM %2. NVDIMM is configured for a
different processor type. All NVDIMMs
on Processor %3 are disabled.
Sanitize the NVDIMM. If the problem persists,
contact your sales representative.
UEFI
379
NVDIMM Error - Processor %1,
DIMM %2. NVDIMM is configured for a
different processor type. NVDIMM has
been disabled.
Sanitize the NVDIMM. If the problem persists,
contact your sales representative.
UEFI
380
NVDIMM Error - Processor %1,
DIMM %2. NVDIMM location changed.
All NVDIMMs on Processor %3 are
disabled.
Install the NVDIMM in the corresponding DIMM
slot, or sanitize the NVDIMM. If the problem
persists, contact your sales representative.
UEFI
381
NVDIMM Error - Processor %1,
DIMM %2. NVDIMM location changed.
NVDIMM has been disabled.
Install the NVDIMM in the corresponding DIMM
slot, or sanitize the NVDIMM. If the problem
persists, contact your sales representative.