1. IML Error Message
Express5800/R120h-1M, R120h-2M Maintenance Guide
197
Chapter 3 Appendix
Class
Error code
Error message
Action
UEFI
1922
Slot %1 Smart Array - More devices
attached than this controller supports.
Some devices are ignored.
Please take actions in the following order.
1. Updating the firmware of the Slot% 1 controller
to the latest version may solve the error. Refer to
the release notes to check if there are related
improvements. If there are related improvements,
update the firmware of the Slot% 1 controller.
2. Reduce the number of hard disk drives
connected to the Slot% 1 controller.
UEFI
1930
Slot %1 Smart Array - Valid data found
in write-back Cache. Data will
automatically be written to the logical
drive(s).
Although the power has been turned off with the
data still in the write-back cache, the data was
automatically written to the logical drive. If the
data is not recorded repeatedly, no action is
required.
To prevent data from remaining in the write-back
cache, perform a normal shutdown of the system.
If the problem persists, contact your sales
representative.
UEFI
1931
Slot %1 Smart Array - Data in
write-back cache has been lost.
Perform the following measures
1. Check the integrity of the data stored in the
drive.
2. To prevent data from remaining in the
write-back cache, perform a normal shutdown of
the system.
3. If the data is missing, restore the previous
backup data.
UEFI
1932
Slot %1 Smart Array - Write-back
cache configuration error. %2
Take either of the following steps.
1. Change the drive array configuration back to
what matches the cache.
2. Clear the data in the cache by executing the
storage software.
UEFI
1933
Slot %1 Smart Array - Consecutive
power loss during I/O transactions on
non-optimal write-back volumes. This
might have resulted in data integrity
issues.
Please take actions in following order.
1. Make sure the controller (card) in slot %1 to be
installed.
2. Make sure the power supply and the batteries
have no problem.
UEFI
1934
Slot %1 Smart Array - Battery is not
present. Caching is disabled.
Install the cache module battery.
UEFI
1935
Slot %1 Smart Array - Battery is
charging. Caching will be enabled once
the battery has been charged.
Action is not necessary.
UEFI
1936
Slot %1 Smart Array - Cache Module
Self-Test Error Occurred. %2
Contact your sales representative.
UEFI
1937
Slot %1 Smart Array - Battery is
present but the controller battery cable
is not attached.
Make sure the battery cable for the controller is
properly connected.
Make sure the cable is properly connected to the
connector.
If the problem persists, contact your sales
representative.
UEFI
1940
Slot %1 Smart Array - The following
logical drives are failed: %2.
Contact your sales representative.