1. IML Error Message
Express5800/R120h-1M, R120h-2M Maintenance Guide
200
Chapter 3 Appendix
Class
Error code
Error message
Action
UEFI
2225
Secure Boot - Unable to reset one or
more keys.
Set the required settings again using the System
Utility after restoring factory default settings by
selecting
System Configuration
>
BIOS/Platform Configuration (RBSU)
>
System Defult Options
-
Restore Default
Manufacturing Settings
options from the menu of
the System Utility. If the problem persists, contact
your sales representative.
UEFI
2226
Secure Boot - Unable to delete one or
more variables.
Set the required settings again using the System
Utility after restoring factory default settings by
selecting
System Configuration
>
BIOS/Platform Configuration (RBSU)
>
System Defult Options
-
Restore Default
Manufacturing Settings
options from the menu of
the System Utility. If the problem persists, contact
your sales representative.
UEFI
2227
Secure Boot - Unable to delete one or
more entries.
Set the required settings again using the System
Utility after restoring factory default settings by
selecting
System Configuration
>
BIOS/Platform Configuration (RBSU)
>
System Defult Options
-
Restore Default
Manufacturing Settings
options from the menu of
the System Utility. If the problem persists, contact
your sales representative.
UEFI
2319
Test event. This is only a test.
Action is not necessary.
UEFI
2400
Slot %1 SAN Error - SAN link is down.
SAN connection not possible.
Confirm the SAN switches and the configuration.
Then reconnect SAN ports or restart the server.
UEFI
2401
Slot %1 SAN Error - Fabric Login
(FLOGI) failed. SAN connection not
possible.
Confirm the SAN switches and the configuration.
Then reconnect SAN ports or restart the server.
UEFI
2402
Slot %1 SAN Error - Name Server login
failed. Boot from SAN not possible.
Confirm the SAN switches and the configuration.
Then reconnect SAN ports or restart the server.
UEFI
2403
Slot %1 SAN Error - No targets found.
Boot from SAN not possible.
Confirm the SAN switches and the configuration.
Then reconnect SAN ports or restart the unit.
UEFI
2404
Slot %1 SAN Error - Adapter restart
failed. Firmware not ready. Boot from
SAN not possible.
Reconnect SAN ports or restart the server. If the
problem persists, contact your sales
representative.
UEFI
2405
Slot %1 Error - Vital Product Data
(VPD) is not available.
Update the firmware of the card in slot %1. If the
problem persists, contact your sales
representative.
UEFI
2406
Slot %1 NIC Error - NIC personality
(Ethernet, iSCSI, or FCoE) could not be
changed. FW may require update.
Update the firmware of the NIC card in slot %1
before restarting the server.
UEFI
2407
Slot %1 Error - The firmware update
did not complete successfully.
Update the firmware of the card again after
confirming the firmware image of the card in
slot %1 is correct.
UEFI
2408
Slot %1 Error - Firmware image
recovery not successful.
Restart the unit. If the problem persists, contact
your sales representative.