1. IML Error Message
Express5800/R120h-1M, R120h-2M Maintenance Guide
201
Chapter 3 Appendix
Class
Error code
Error message
Action
UEFI
2409
Slot %1 Error - Failure to apply Virtual
Connect (VC) settings.
Confirm the VC configuration. Apply the VC
configuration again after restarting the server.
UEFI
2410
Slot %1 Error - Controller I/O timeout
failure.
Restart the unit. If the problem persists, contact
your sales representative.
UEFI
2411
%1: iSCSI Error - Failed to acquire
DHCP client network address.
Check the network cables and the DHCP server
configuration. Restart the server.
UEFI
2412
%1: iSCSI Error - Failed to acquire
DHCP target network address.
Check the network cables and the DHCP server
configuration. Restart the server.
UEFI
2413
%1: iSCSI Error - Failed to acquire
DHCP iSNS Server IP address.
Check the network cables, the DHCP server
configuration and the iSNS server configuration.
Restart the server.
UEFI
2414
%1: iSCSI Error - iSCSI login failed.
Confirm and set the cable connection, the
controller configuration, and the configurations of
iSCSI initiator and the target properly. Then restart
the server.
UEFI
2415
%1: iSCSI Error - Boot LUN not
available.
Confirm and set the controller configuration and
the iSCSI server configuration properly. Then
restart the server.
UEFI
2416
%1: Error - Controller firmware not
ready.
Restart the unit. If the problem continues, update
FW. If the problem persists, contact your sales
representative.
UEFI
2419
%1 %2 Error - Rx/Tx is disabled on this
device because an unsupported SFP+
or QSFP module type was detected.
Contact your sales representative.
UEFI
2420
%1 %2 Error - The UEFI driver for the
device detected an older version of the
NVM image than expected.
Update the NVM image. If the problem persists,
contact your sales representative.
UEFI
2421
%1 %2 Error - The UEFI driver for the
device detected a newer version of the
NVM image than expected.
Update the NVM UEFI driver to the latest version. If
the problem persists, contact your sales
representative.
UEFI
2422
%1 %2 Error - The UEFI driver for the
device stopped because the NVM image
is newer than expected.
Update the NVM UEFI driver to the latest version. If
the problem persists, contact your sales
representative.
UEFI
3100
Trusted Platform Module (TPM) was
successfully bound to system.
Action is not necessary. The unit restarts
automatically.
UEFI
3101
Unbound Trusted Platform Module
(TPM) detected.
Action is not necessary. The TPM is integrated into
the unit after being cleared.
UEFI
120
A Critical Error Event that has kept the
system from booting. -System Halted!
Contact your sales representative.
UEFI
163
Time & Date Not Set.
Set the date and time of the server.
UEFI
209
Unsupported DIMM Configuration
Detected - Installed DIMM
configuration does NOT support
configured AMP Mode. System will
operate in Advanced ECC Mode. (Major
Code:%1 Minor Code:%2).
For the details of the DIMM configuration required
to use the AMP mode, refer to the
User's Guide
.
If the problem persists, contact your sales
representative.