1. IML Error Message
Express5800/R120h-1M, R120h-2M Maintenance Guide
190
Chapter 3 Appendix
Class
Error code
Error message
Action
UEFI
394
NVDIMM Error - Processor %1,
DIMM %2 (SN:%3-%4-%5-%6).
Unable to set event notification for this
NVDIMM to generate alerts for health
changes, including a loss of data
persistency.
Updating the system ROM and the innovation
engine firmware may solve the error. Please update
the system ROM and the innovation engine
firmware.
If the problem persists, contact your sales
representative.
UEFI
395
NVDIMM Error - Processor %1,
DIMM %2 (SN:%3-%4-%5-%6).
NVDIMM Persistency is lost and future
data backup is not available.
Please take actions in following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
UEFI
396
IMPORTANT: Processor %1, DIMM %2 -
NVDIMM Persistency is restored and
future data backup is available.
Action is not necessary.
UEFI
397
WARNING: Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM
lifetime has reached.
Please take actions in following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
UEFI
398
NVDIMM Configuration Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). Backup power is
not available to this DIMM slot.
NVDIMM is disabled.
Install the NVDIMM in the slot where the NVDIMM
is available. If the problem persists, contact your
sales representative.
UEFI
399
INFORMATION: Processor %1,
DIMM %2 (SN:%3-%4-%5-%6).
Extended Diagnostic Information
(Data1 = 0x%7, Data2 = 0x%8, Data3
= 0x%9, Data4 = 0x%10).
Action is not necessary.
However, if the error is recorded repeatedly, please
contact your sales representative.
UEFI
400
Intrusion Alert Detection - The server
chassis hood is currently not installed.
An intrusion warning has been detected. The cover
of the server has not been installed. Check the
installation of the cover.
If the problem persists, contact your sales
representative.
UEFI
401
Intrusion Alert Detection - The server
chassis hood was removed prior to this
power on.
An intrusion warning has been detected. It
detected that the server cover has been once
removed. Check the status of the server.
If the problem persists, contact your sales
representative.
UEFI
402
Intrusion Alert Detection - The required
intrusion detection cable is missing.
An intrusion warning has been detected. The
intrusion detection cable is not connected. Check
the status of the server.
If the problem persists, contact your sales
representative.
UEFI
403
Intrusion Alert Configuration Error -
Intrusion Alert Detection cable is
installed but the feature is not enabled.
An intrusion warning has been detected. While the
intrusion detection cable has been connected, its
function is not enabled. Check the settings of the
server.
If the problem persists, contact your sales
representative.