Configuring Your Server 4-71
The Write Policy has the following modes depending on combination with WrtThru for BAD BBU.
Select a mode suitable for your environment.
WrtThru for BAD BBU
Checked
Unchecked
WBack
Normal write back mode
* There is no additional battery for
the controller, so the controller
operates in write through mode.
Constant write back mode
The controller always uses cache
memory for writing regardless of battery
charged status or existence of battery.
Be sure to use UPS when specifying
this mode for write policy.
Write
Policy
WThru
Write through mode
The controller does not use cache
memory for writing data.
This mode can provide the highest
data security, however, the writing
performance is lower than that in
write back mode.
* This mode is unavailable.
If you do not check "WrtThru for BAD
BBU" at creation of VD, this item is
automatically checked after the VD has
been created.
IMPORTANT:
If constant write back mode is selected, the controller operates in
write back mode even if the battery has failed, insufficiently charged,
or no battery has been installed. The data in cache memory may be
lost at an occurrence of power failure.
Be sure to use UPS when specifying the constant write back mode
for write policy.
Summary of Contents for Express5800/B120b
Page 14: ...viii This page is intentionally left blank ...
Page 97: ...Configuring Your Server 4 47 Property of Hard disk drive of Universal RAID Utility ...
Page 194: ...5 58 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 224: ...7 6 Maintenance This page is intentionally left blank ...
Page 300: ...9 38 Upgrading Your Server This page is intentionally left blank ...
Page 302: ...A 2 Specifications This page is intentionally left blank ...
Page 377: ...Installing the Operating System B 75 4 Activate Windows The Windows activation is complete ...
Page 382: ...B 80 Installing the Operating System This page is intentionally left blank ...