Troubleshooting 8-7
On-screen error message
Action
Foreign configuration(s) found on adapter
Press any key to continue, or 'C' to load the configuration utility.
Press C to run the utility to import
or clear configuration.
Invalid SAS Address present in MFC data. Please program
valid SAS Address, and restart your system.
Please contact your service
representative.
Invalid SAS topology detected. Please check your cable
configurations, repair the problem, and restart your system.
Check if RAID Controller is
connected properly. If the same
error persists, contact your
service representative.
Invalid memory configuration detected.
Please contact your system support.
System has halted.
Contact your service
representative to replace the
RAID Controller.
Memory/battery problems were detected.
The adapter has recovered, but cached data was lost.
Press any key to continue, or 'C' to load the configuration utility.
Please contact your service
representative.
Multibit ECC errors were detected on the controller.
DIMM on the controller needs replacement. If you continue,
data corruption can occur. Press 'X' to continue or else power
off the system and replace the DIMM module and reboot. If you
have replaced the DIMM please press 'X' to continue.
Contact your service
representative to replace the
RAID Controller
Multiple Single-bit ECC errors were detected during the
previous boot of the controller. DIMM on the controller needs
replacement.
If you continue, data corruption can occur.
Press 'X' to continue or else power off the system and replace
the DIMM module and reboot. If you have replaced the DIMM
please press 'X' to continue.
Contact your service
representative to replace the
RAID Controller
Previous configuration cleared or missing
Importing configuration created on MM/DD hh:mm
Press any key to continue, or 'C' to load the configuration utility.
Please contact your service
representative.
RAID Adapter
FW Failed Validation!!!
Adapter needs to be reflashed.
Press any key to continue.
Contact your service
representative to replace the
RAID Controller.
SAS drives were detected, but this controller does not support
SAS drives.
Please remove the SAS drives then restart your system.
Press any key to continue, or 'C' to load the configuration utility.
RAID Controller may be faulty.
Contact your service
representative to replace the
RAID Controller.
SATA drives were detected, but this controller does not support
SATA drives.
Please remove the SATA drives then restart your system. Press
any key to continue, or 'C' to load the configuration utility.
RAID Controller may be faulty.
Contact your service
representative to replace the
RAID Controller.
Single-bit overflow ECC errors were detected during the
previous boot of the controller. DIMM on the controller needs
replacement.
If you continue, data corruption can occur.
Press 'X' to continue or else power off the system and replace
the DIMM module and reboot. If you have replaced the DIMM
please press 'X' to continue.
Contact your service
representative to replace the
RAID Controller
Summary of Contents for Express5800/B120b
Page 14: ...viii This page is intentionally left blank ...
Page 97: ...Configuring Your Server 4 47 Property of Hard disk drive of Universal RAID Utility ...
Page 194: ...5 58 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 224: ...7 6 Maintenance This page is intentionally left blank ...
Page 300: ...9 38 Upgrading Your Server This page is intentionally left blank ...
Page 302: ...A 2 Specifications This page is intentionally left blank ...
Page 377: ...Installing the Operating System B 75 4 Activate Windows The Windows activation is complete ...
Page 382: ...B 80 Installing the Operating System This page is intentionally left blank ...