General Description 2-11
Virtual LCD indications when STATUS lamp is flashing in red
On-screen message
Description
Action
Proc 1 IERR
An error was detected in CPU#1.
Proc 2 IERR
An error was detected in CPU#2.
WDT Timeout
Watchdog timer timeout error
occurred.
WDT Power Down
Forcedly powered off due to
watchdog timer timeout error.
SMI Timeout
A timeout error occurred while the
system management interrupt
process is in progress.
Turn of the power once and then
on again.
If an error message appears on
POST screen, take note of the
message, and contact your service
representative.
If no error message appears,
check the IPMI information by
using the Off-line Maintenance
Utility.
ErrPause in POST
The system is waiting for key entry
due to serious POST error.
Check the error message on
POST screen, take note of it, and
contact your service
representative.
DUMP Request !
Under memory dump request
Wait until dump collection
completes.
CPU1_DIMM U-Err
An uncorrectable memory error was
detected on CPU1_DIMM.
CPU2_DIMM U-Err
An uncorrectable memory error was
detected on CPU2_DIMM.
Check installation status DIMM.
If the same error persists, contact
your service representative.
Proc Missing
No CPU is installed in slot CPU#1.
Proc1 Config Err
The CPU installed in the CPU#1 slot
is unsupported or its combination is
illegal.
Proc2 Config Err
The CPU installed in the CPU#2 slot
is unsupported or its combination is
illegal.
Check installation status of CPU.
If the same error persists, contact
your service representative.
MEZ1 Power Fault
An error was detected in power
circuit of mezzanine card installed in
Type 1 slot of CPU blade.
MEZ2 Power Fault
An error was detected in power
circuit of mezzanine card installed in
Type 2 slot of CPU blade.
Check installation status of
mezzanine card.
If the same error persists, contact
your service representative.
IOH Thermal Trip
Forced power-off occurred due to a
thermal error in chipset on CPU
blade.
Proc1ThermalTrip
Forced power-off occurred due to a
thermal error in CPU#1.
Proc2ThermalTrip
Forced power-off occurred due to a
thermal error in CPU#2.
Proc1 Therm % 09
A high temperature error was
detected in CPU #1.
Proc2 Therm % 09
A high temperature error was
detected in CPU #2.
CPUx_DIMMyTemp09
A high temperature error was
detected in DIMM. x denotes CPU
number, and y denotes DIMM slot
number.
AmbientTempAlm09
A high temperature error was
detected in CPU blade.
Check installation status of the
heat sink on the CPU blade.
Check if fans in Blade Enclosure
work normally.
Refer to the User’s Guide of the
Blade Enclosure to make sure that
the sufficient number of fans are
installed in correct locations.
Check if the fans and CPU blades
are installed in correct locations.
Check if the ambient temperature
of installation location satisfies the
operation guarantee condition.
If the same error persists, contact
your service representative.
Summary of Contents for Express5800/B120b
Page 14: ...viii This page is intentionally left blank ...
Page 97: ...Configuring Your Server 4 47 Property of Hard disk drive of Universal RAID Utility ...
Page 194: ...5 58 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 224: ...7 6 Maintenance This page is intentionally left blank ...
Page 300: ...9 38 Upgrading Your Server This page is intentionally left blank ...
Page 302: ...A 2 Specifications This page is intentionally left blank ...
Page 377: ...Installing the Operating System B 75 4 Activate Windows The Windows activation is complete ...
Page 382: ...B 80 Installing the Operating System This page is intentionally left blank ...