Menu Tree
Setting list
+: Selection/execution parameter
: Setting parameter.
•
: Information display
>: Can be set (modified) after creation of virtual drive
Menu
Description
+Configure
Performs Configuration settings
+Easy Configuration
Set configuration (Using fixed value)
+New Configuration
Set new configuration
+View/Add Configuration
Additional setting / viewing configuration
+Clear Configuration
Clear configuration
+Select Boot Drive
Choose Bootable Virtual Drive
+Initialize
Initialize Virtual Drive
+Objects
Various settings
+Adapter
Set RAID controller
+Sel. Adapter
Clear configuration
Rebuild Rate
30
Chk Const Rate
30
FGI Rate
30
BGI Rate
30
Disk WC
Off
Read Ahead
On
Bios State
Enable
Cont on Error
Yes
Fast Init
Enable
Auto Rebuild
On
Auto Resume
Enable
Disk Coercion
1GB
Factory Default
Set to default value
+Virtual Drive
Virtual drive operation
+Virtual Drives
Select virtual drive (when multiple virtual drives exist)
+Initialize
Initialize virtual drive
+Check Consistency
Check virtual drive redundancy
+View/Update Parameters
Display virtual drive information
•
RAID
Display RAID level
•
SIZE
Display virtual drive capacity
•
Stripe SIZE
Display stripe size
•
#Stripes
Display the number of hard disk drives in virtual drive
•
State
Display virtual drive status
•
Spans
Display setting of spanning
•
Write Cache
Display setting of write cache
•
Read Ahead
Display setting of read ahead
+Physical Drive
Physical drive operation
+Physical Drive Selection Menu
Select physical drive
+Make HotSpare
Set as hot-spare disk for auto rebuilding
+Force Online
Make a disk online
+Change Drv State
Make a disk offline or make a hot-spare ready
+Device Identification
Display hard disk drive information
•
Device Type
Hard disk drive type
•
Capacity
Hard disk drive capacity
•
Product ID
Hard disk drive model
•
Revision No.
Hard disk drive revision
+Rebuild
Perform rebuilding
+Check Consistency
Perform virtual drive redundancy check
Summary of Contents for Express5800/B120b
Page 14: ...viii This page is intentionally left blank ...
Page 97: ...Configuring Your Server 4 47 Property of Hard disk drive of Universal RAID Utility ...
Page 194: ...5 58 Installing the Operating System with Express Setup This page is intentionally left blank ...
Page 224: ...7 6 Maintenance This page is intentionally left blank ...
Page 300: ...9 38 Upgrading Your Server This page is intentionally left blank ...
Page 302: ...A 2 Specifications This page is intentionally left blank ...
Page 377: ...Installing the Operating System B 75 4 Activate Windows The Windows activation is complete ...
Page 382: ...B 80 Installing the Operating System This page is intentionally left blank ...