9-48 Upgrading Your Server
Removal
1.
See section "Preparing for Installation and Removal" described earlier to prepare.
IMPORTANT:
The remote management card logic monitors and logs
system voltage changes. When removing the RMC from the
motherboard, you may experience a 3 - 4 second delay from the time
your system powering down.
2.
Open the levers on the both sides of the RMC connector to unlatch the RMC.
3.
Remove the RMC from the connector.
4.
Run BIOS SETUP utility and check to see that [Event Log Configuration] is not displayed
in the [Server] menu.
See Chapter 4 for details.
5.
Run BIOS SETUP utility and select "Yes" for [Reset Configuration Data] in the
[Advanced] menu.
This setting is required to change the hardware configuration data. See Chapter 4 for
details.
6.
Override installation of NEC ESMPRO Agent if installed.
To collect the system information and event log from the management PC, NEC
ESMPRO Agent must be installed in the server.