Tie Line Incoming
Interdigit Timeout
Selection
3-24
The maximum time an address
signal is missing during
incoming call detection before
an error tone is returned to the
other system.
1s
6s
∞
Tie Line Wink/Delay
Signal Detect
Timeout Selection
3-25
The maximum time for
receiving an acknowledgment
signal from a distant system
before sending a busy tone.
1s
7s
∞
Disconnect
Recognition Time
Selection
3-33
The minimum time (seconds)
before a disconnected circuit
can be accessed again.
0
0.3
1.5
Automatic Release
Signal Detection
Selection
3-40
The Signal detection time
(milliseconds) for CO/PBX line
release after a disconnect
signal is received from the
distant CO or PBX.
0
350
∞
DIT/ANA Delay
Answer Time
Selection
3-61
The time an incoming CO/PBX
call rings before changing to a
DIT/ANA call.
0s
0s
60s
Table A-1 Function Time Chart (Continued)
Time
Memory
Block
Definition
Value
Minimum
Default