2 - 330
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1
Electra Elite IPK
1-15-14 Centralized Day/Night Switching for
Main Office Assignment
General Description
Use this Memory Block to activate
K-
CCIS by assigning a Main or Remote system.
Display
Programming Procedures
1
Go off-line.
2
Press LK1 + LK15 +
AB
to access the Memory Block.
3
Use dial pad keys to enter Table number, C-Channel, and Point Code.
Use the following to enter data:
J
to move cursor left
L
to move cursor right
K
~
I
to enter numeric data
Point code range is 00001~16367.
Tables 01~16 can be assigned.
Default Values:
All Tables Not Specified
4
Press
G
to write the data, and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
7-1
Card Interface Slot Assignment
7-3-01
MIF (LCR) Assignment
7-3-02
MIF (SMDR) Assignment
1-15-00
K-CCIS Main/Remote Office Selection
1-15-01
Common Signal Channel Data Speed Assignment
1-15-02
Common Signal Channel Assignment
1-15-03
Originating Point Code Assignment
1-15-04
Destination Point Code Assignment
1-15-05
Destination Point Code Transfer Assignment
System Mode
1
Submode
15
Data No.
14
PC Programming
¦
+AW
1 4 : T 0 1 :
=
0
T I M E
D I S P L A Y
Data
No.
Point
Code
Table
01~16
C-Ch
1~4
Summary of Contents for ElectraElite IPK