Elite IPK
Document Revison 1
Programming Manual
2 - 485
___________________________________________________________________________________
___________________________________________________________________________________
4-30
Hold/Transfer Recall Display
Selection
General Description
Use this Memory Block to enable/disable the Hold Recall indication on the LCD.
Display
Settings
Notes
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
YS
NO
Programming Procedures
1
Go off-line.
2
Press LK4 +
CK
to access the Memory Block.
3
Press LK2 to disable Hold Recall LCD Indication for Tel Port No.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data or Tel Port No.
– OR –
D
to go to next assigned Tel Port No.
B
+
A
to enter A for Port Numbers 100~109
B
+
B
to enter B for Port Numbers 110~119
B
+
C
to enter C for Port Number 120
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
G
to go back on-line.
1.
When this Memory Block is assigned YS, HOLD RECALL replaces the Time Display.
2.
LCD indication of the CO line number is displayed on the upper line of the display when a recall occurs,
regardless of the assignment for this Memory Block.
3.
Telephone ports A0~C0 are ports 100~120.
Telephone Mode
4
Submode
—
Data No.
30
PC Programming
¦
+BTM
Data
No.
0 1 / 3 0 : H L D
D S P
Y S
T I M E
D I S P L A Y
Tel
Port
No.
(01
~
C0)
Title
Setting
Data
Summary of Contents for ElectraElite IPK