1 - 28
Multiline Terminal Programming
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1
Elite IPK
07
K-CCIS Message Response
Timeout Assignment
30 sec
Valid Times: 01~99 Seconds
08
Link Reconnect Allow/Deny
Selection
YS
NO, YS
09
K-CCIS Maximum Call Forwarding
Hop Assignment
5
1~7
10
Calling Name display Allow/Deny
Selection
NO
NO, YS
11
Centralized Billing Allow/Deny
Selection
NO (Deny)
NO (Deny), YS (Allow)
12
Centralized Billing – Point Code of
Center Office Assignment
Blank
Point Code Range: 00001~16367
13
Centralized Day/Night Switching for
Remote Office Assignment
NO (Deny)
NO (Deny), YS (Allow)
14
Centralized Day/Night Switching for
Main Office Assignment
All Tables Not
Specified
Table Range: 01~16
Point Code Range: 00001~16367
LK 1 System Mode
LK 15 K-CCIS (Continued)
Data
No.
Memory Block Name
Default Value
Programming Values
LK 1 System Mode
LK 16 HUB
Data
No.
Memory Block Name
Default Value
Programming Values
00
Auto Negotiation Yes/No Selection
YS (Enable)
YS, NO
01
Port Speed Selection – 10/100
Base-T
100 (100 Base-TX)
10 (10 Base-T), 100
(100 Base-TX)
02
Port Duplex Mode Selection
HALF
HALF, FULL
03
MDI/MDIX Mode Selection
AUTO
MDIX, MDI, AUTO
04
VLAN Mode Selection
NO (Disable)
NO, YS (Enable)
05
Default VLAN ID Assignment
0001 (0x001 Hex.)
0001~4095 (0x001~0xfff Hex.)
06
Port Based Priority Selection
NO (Not Assigned)
NO, LO (Low), HI (High)