2 - 82
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1
Elite IPK
1-1-71
First Delay Announcement Start Time
Selection
General Description
Use this Memory Block to specify the time between receiving a CO call and sending a
First Delay Announcement to the calling party.
Display
Settings
Notes
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default. Times
are in seconds.
00
10
20 30 40 50
60
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 +
GA
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-1-72
First Delay Announcement Repeat Selection
1-8-13
VRS Message Function Assignment
3-41
Delay Announcement Assignment
This Memory Block does not display unless the MIFA-U ( ) ETU is installed.
System Mode
1
Submode
1
Data No.
71
PC Programming
¦
+AR
7 1 : M S G
S T A R T = 2 0
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data
Summary of Contents for ElectraElite IPK
Page 2: ...PROGRAMMING MANUAL Stock Number 750825 Document Revision 1 Release 1000...