1 - 30
Multiline Terminal Programming
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1
Elite IPK
LK 3 CO/PBX Line Mode
Data
No.
Memory Block Name
Default Value
Programming Values
00
Trunk Name/Number Assignment
Not Specified
Maximum of 13 digits (numbers, hyphens,
and spaces)
02
Trunk Status Selection
OUT&IN
OUT&IN, IN
03
Trunk-to-Trunk Group Assignment
01
Refer to
3-03 Trunk-to-Trunk Group
Assignment on page 2-381
.
04
Trunk-to-Trunk Transfer Yes/No
Selection
NO
NO, YES
05
Trunk Incoming Answer Mode
Selection
NO ASSIGN
NO ASSIGN, TANDM TRF, AA
06
Automatic Tandem Trunk
Assignment
Not Specified
CO 01~64
07
CO/PBX Ringing Variation Selection
M
M, L, H
11
CO External Source Selection
CO
CO, EXT SOURCE
12
Trunk-to-MOH Trunk Assignment
00
01~64 CO/PBX
14
Tie Line Type Assignment
2ND DIAL
2ND DIAL, IMMEDIATE, DELAY, WINK
15
Trunk DTMF Duration/Interdigit
Selection
110 /80
Duration / Interdigit Time in milliseconds:
60/70, 60/80, 110/80, 160/80, 210/80,
410/100, 610/100, 810/190.
16
Tie Line Prepause Time Selection
0
In seconds:
0, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0,
8.0, 9.0, 10.0, 11.0, 12.0,13.0
17
Tie Line Answer Detect Time
Selection
520
In milliseconds:
0, 130, 260, 390, 520, 650, 780, 910, 1040,
1170, 1300, 1430, 1560, 1690, 1820, 1950
18
Tie Line Release Detect Time
Selection
520
In milliseconds:
0, 130, 260, 390, 520, 650, 780, 910, 1040,
1170, 1300, 1430, 1560, 1690, 1820, 1950
19
Tie Line/CO/PBX Incoming Signal
Detect Time Selection
03
Refer to
3-19 Tie Line/CO/PBX Incoming
Signal Detect Time Selection on page
2-398
.
20
Tie Line Loop Off-Guard Time
Selection
2.0
In seconds:
0.0, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0,
8.0, 9.0, 10.0, 11.0, 12.0, 13.0
Summary of Contents for ElectraElite IPK