Elite IPK
Document Revision 1
Programming Manual
2 - 73
___________________________________________________________________________________
___________________________________________________________________________________
1-1-63
Hold Recall Time Selection
(Exclusive)
General Description
Use this Memory Block to specify the time for Exclusive Hold Recall. If No Limit is
selected, Exclusive Hold Recall is not provided.
Display
Settings
Notes
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default. Times
are in minutes.
0.5
1.0
1.5
2.0
3.0
5.0
8.0
∞
(
No Limit)
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1 +
FC
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-1-03
Hold Recall Time Selection (Non-Exclusive Hold)
1-2-23
System Call Park Recall Time Selection
When an Exclusive Hold call recalls, the held call switches to a Non-Exclusive Hold call.
System Mode
1
Submode
1
Data No.
63
PC Programming
¦
+BM
6 3 : H O L D
R E C L
1 . 0
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data
Summary of Contents for ElectraElite IPK