2 - 134
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1
Elite IPK
1-4-04
Tandem Transfer SMDR Print
Extension Assignment
General Description
Use this Memory Block to specify a special number to be output from Station Message
Detail Recording (SMDR) to indicate an automatic trunk-to-trunk transfer.
Display
Notes
Programming Procedures
1
Go off-line.
2
Press LK1 +
LK4 +
JD
to access the Memory Block.
3
Use the dial pad to enter the Table Number and Setting Data.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
Setting Data (Allowed):
2-Digit Number:
00~99
3-Digit Number:
000~999
4-Digit Number:
0000~9990
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-2-03
2-, 3-, or 4-Digit Station Number Selection
1.
When the system is powered up initially, this block defaults to 3-digit number 999.
2.
When 2-digit station numbers are selected, this block defaults to 99.
3.
When 4-digit station numbers are selected, this block defaults to 9999.
System Mode
1
Submode
4
Data No.
04
PC Programming
¦
+AT
0 4 : T A N D
E X T = 9 9 9
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data
Default Values
3-digit number = 999