MIF (ACD) Assignment
General Description
Use this Memory Block to enable the Automatic Call Distribution (ACD) function of the
MIFA-U( ) ETU.
Display
Notes
Programming Procedures
1
Go off-line.
2
Press LK7 + LK3
to access the Memory Block.
3
Use the dial pad to enter data.
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
Setting Data: 00, 01, 02
Default Values
No Assignment (00)
4
Press
G
to write the data.
5
Press
E
to go back on-line.
The ACD feature requires a KMA(1.0)U to be installed on the MIFA-U( ) ETU.