Second Initialization
General Description
Use this Memory Block to initialize all the system hardware. All system software and
user programming are retained after the Second Initialization.
Display
Programming Procedures
1
Go off-line.
2
Press LK8 + LK8 to access the Memory Block.
3
When the system display prompt indicates CPU RESET?, the first four CO/PBX lines light red.
4
Press
HHKK
to enter the fixed password.
When each number of the password is being entered, the applicable top line CO/PBX LED changes from red to green.
5
Press
G
to begin the initialization process.
6
Press
E
to go back on-line.