Elite IPK
Document Revision 1
Programming Manual
2 - 141
___________________________________________________________________________________
___________________________________________________________________________________
1-4-14
Automated Attendant Message Access
Code (1-Digit) Assignment
General Description
Use this Memory Block to specify a 1-digit code to route an incoming call from the
Automated Attendant.
Display
.
Related Programming
Refer to individual features in the Electra Elite IPK Features and Specifications Manual.
Programming Procedures
1
Go off-line.
2
Press LK1 + LK4 +
JJAD
to access the Memory Block.
3
Use the dial pad to enter function code for AA MSG. 1, Dial No. 0.
Use
K
~
I
to enter the function code.
Setting Data (Allowed):
Function Code 001~053
000 is unused.
4
Press
G
to write the data and advance to the next dial number.
5
Repeat Steps 3 and 4 for each Dial No. AA MSG. 2, Dial No. 0 is displayed.
6
Repeat Steps 3 and 4 for each Dial No. AA MSG. 3, Dial No. 0 is displayed.
7
Continue this cycle for all Dial NOs. for all messages. The next Memory Block is displayed.
8
Program the next Memory Block or press
E
to go back on-line.
System Mode
1
Submode
4
Data No.
14
PC Programming
¦
+AU
1 4 : A A
A C
1 - O = 0 3 0
T I M E
D I S P L A Y
Data
No.
AA MSG.
(1~8)
Title
Function
Code
DIAL.
No.
(0~9)
Default Values
Dial
Number
Function
Code
Contents
0
030
Specified
Station Call (0)
1
010
Station Number
2
010
Station Number
3
010
Station Number
4 ~ 9
000
Unregistered