1 - 26
Multiline Terminal Programming
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1
Elite IPK
LK 1 System Mode
LK 12 ACD/UCD
Data
No.
Memory Block Name
Default Value
Programming Values
00
ACD/UCD Group Pilot Number
Assignment
Not Specified
Any Unused Extension Number
01
ACD/UCD Group Overflow
Destination Assignment
Not Specified
Any Unused Extension Number
02
ACD/UCD Overflow Time Selection
60s
In seconds:
∞
, 10s, 20s, 30s, 60s,120s,
180s, 240s
LK 1 System Mode
LK 13 PRT
Data
No.
Memory Block Name
Default Value
Programming Values
00
PRT Channel Assignment
24
0, 4, 8, 12, 16, 20, 24
01
PRT Signal Format Selection
24
12 (SF), 24 (ESF)
02
Clear Channel Selection
ZCS
ZCS, B8ZS
03
Call by Call Service Selection
NO
YS, NO
04
PRT B Channel Outgoing Priority
Selection
H
→
L
H
→
L, L
→
H
05
PRT B Channel-to-Trunk Group
Assignment
00 (Any Trunk Group)
00, 01~32 Trunk Groups
Summary of Contents for ElectraElite IPK