![background image](http://html1.mh-extra.com/html/nec/electraelite-ipk/electraelite-ipk_programing-manual_3863195077.webp)
2 - 6
Memory Blocks
___________________________________________________________________________________
___________________________________________________________________________________
Document Revison 1
Elite IPK
1-1-03
Hold Recall Time Selection
(Non-Exclusive Hold)
General Description
Use this Memory Block to specify the time a Non-Exclusive Hold outside call is held
before a recall tone is generated. When
no Limit is selected, the hold recall alarm tone
is not generated.
Display
Settings
Notes
LK 1
LK 2
LK 3
LK 4
LK 5
LK 6
LK 7
LK 8
The shaded
selection is the
default.
25s
45s
60s
90s
120s
180s
240s
∞
(No Limit)
Programming Procedures
1
Go off-line.
2
Press LK1 + LK1
+
KC
to access the Memory Block.
3
Press the corresponding CO/PBX line key to change the data option.
4
Press
G
to write the data and display the next Memory Block.
5
Program the next Memory Block or press
E
to go back on-line.
Related Programming
M.B. Number
Memory Block Name
1-1-63
Hold Recall Time Selection (Exclusive)
1-2-23
System Call Park Recall Time Selection
1.
Calls put on Exclusive Hold, recall using the data selected in Memory Block 1-1-63 [Hold Recall Time Selection
(Exclusive)].
2.
Calls placed on hold on Call Appearance keys, recall using this Memory Block.
3.
Calls parked in System Call Park locations recall using Memory Block 1-2-23 (System Call Park Recall Time
Selection).
System Mode
1
Submode
1
Data No.
03
PC Programming
¦
+BM
0 3 : H O L D
R E C L
2 5 s
T I M E
D I S P L A Y
Data
Setting
Title
Data
No.
Summary of Contents for ElectraElite IPK
Page 2: ...PROGRAMMING MANUAL Stock Number 750825 Document Revision 1 Release 1000...
Page 3: ......
Page 5: ......