Test Mode
Troubleshooting
69
Mini Puck Low W
arning and
Adding Mini Pucks
7. Operation
7-10 Mini Puck Low Warning and Adding Mini Pucks
7-10-1 Mini Puck Low Warning
When the mini puck low warning ON/OFF setting mode is set to ON and the number of mini pucks
decreases by 50 or more, the 4-digit score in the left side score LED (signboard) blinks while the machine
is in the standby state.
z
When this blinking is confi rmed, add mini pucks.
Score LED
Blinks
Time LED
7-10-2 Adding Mini Pucks
When the mini puck low warning is displayed or the number of mini pucks is otherwise con
fi
rmed to have decreased,
follow the procedure below to add mini pucks.
Block the goals so that mini pucks cannot enter.
Use Test mode and release all of the mini pucks to the playing
fi
eld. (See “7-8-7 S Hopper Motor
ON/OFF Test and Sensor Check” on page 48.)
Count the number of mini pucks, and add mini pucks so that there is a total of 120 pucks.
Unblock the goal (L) so that the mini pucks can enter.
Put the mini pucks into the goal (L).
z
Put the mini pucks into the goal (L) one to three pucks at a time. If many pucks are
put into the goal at once, the pucks may become jammed inside the machine and
prevent normal operation.
z
Be sure to put the mini pucks into the goal (L).
Reset the decrease count of the mini puck low warning to “0”. (See “7-9-9 Mini puck low warning
ON/OFF” on page 60.)
M259_07_ENin6.indd 69
M259_07_ENin6.indd 69
2/5/2013 8:07:01 AM
2/5/2013 8:07:01 AM