111
Test Mode
Inspection and Service
Troubleshooting
8B. Service
- Must be performed by a technician -
(2) Cleaning the Rail (L) and (R) Assemblies
The description below explains how to clean the (L) side. Follow the same procedure to clean the (R) side.
z
To avoid electric shock, accidents or injuries to yourself or other people, or damage to the electronic
circuits, be sure to turn off the power switch before starting work.
z
Do not use thinner, benzene, gasoline, alcohol or other organic solvents. This may
degrade the materials.
Turn off the power switch. (See “7-6-1 Turning the Power Switch On” on page 39.)
Remove the rail (L) assembly by reversing the installation procedure. (See steps
-
of
“8A-2-5 Installing the Side Tower Assembly” on page 96.)
Wipe away any dirt from the puck paths using a soft cloth moistened with water or a neutral
cleanser diluted with water and then
fi
rmly wrung out.
* Use a cotton swab to clean narrow parts.
Rail (L) assembly
Puck path
Rail (R) assembly
Puck path
Wipe dry using a soft cloth so that no water or detergent remains, and then allow to dry completely.
To install, perform the procedure in reverse.