131
Test Mode
Troubleshooting
8B. Service
Troubleshooting
- Must be performed by a technician -
8B-3-1 Overall
Symptom
Main cause
Action
Reference
page
The machine does not start
even when the power switch
is turned on.
The power cord is disconnected
from the outlet or the machine, or is
not connected securely.
•
Connect the power cord correctly
and securely.
•
Turn on the power switch again.
Page 106
The PCB base is not installed
correctly.
Install the PCB base correctly.
Page 146
Main PC board malfunction.
Replace the main PC board.
Page 146
Switching regulator malfunction.
Replace the switching regulator.
Page 148
Operation is not stable.
The power supply voltage is not
within the range of AC 110 V to
130 V (or 210 V to 230 V).
Disconnect any high-capacity
devices (such as an air conditioner
or large machine) from the same
line to secure the speci
fi
ed power
supply voltage.
─
The power turns off during
operation.
The circuit protector has operated to
turn off the power switch.
* The circuit protector turns off the
current when an abnormal current
occurs.
Turn on the power switch again.
If the circuit protector operates
frequently, there is a mechanical
abnormality.
Contact your distributor.
─
8B-3-2 Table top assembly
Symptom
Main cause
Action
Reference
page
The pucks do not slide.
The machine is in Attract (standby)
mode.
When the game starts, the blower
fan operates so that the pucks slide.
Page 40
The inside of the playing
fi
eld.
Clean the playing
fi
eld.
Page 70
A puck is deformed.
Replace the deformed puck with a
spare puck.
Page 105
A puck is dirty.
Clean the puck.
Page 71
The blower fan malfunction.
Replace the blower fan.
Page 139
SSR malfunction.
Replace the SSR.
Page 149
M259_08B_ENin6.indd 131
M259_08B_ENin6.indd 131
2/5/2013 8:11:54 AM