8B. Service
- Must be performed by a technician -
8B-4-5
Hopper
assembly
(1) Replacing the L Hopper Motor
z
To avoid electric shock, accidents or injuries to yourself or other people, or damage to the electronic
circuits, be sure to turn off the power switch before starting work.
Turn off the power switch. (See “7-6-1 Turning the Power Switch On” on page 39.)
Remove the side tower assembly by reversing the installation procedure. (See steps
-
of “8A-2-5 Installing the Side Tower Assembly” on page 96.)
Remove the wing bolt (M4 x 6), and remove the L hopper cover.
L hopper cover
Wing bolt (M4 x 6)
Remove the cord clip and disconnect the connector.
Connector
Cord clip