112
8B. Service
- Must be performed by a technician -
(3) Cleaning the Insides of the L and S Buckets (Hopper Assembly)
z
To avoid electric shock, accidents or injuries to yourself or other people, or damage to the electronic
circuits, be sure to turn off the power switch before starting work.
z
Do not perform the following operations. Doing so may cause pucks to jam or other
malfunctions.
•
Rotating the L hopper disk in the clockwise direction as viewed from above.
•
Rotating the S hopper disk in the counter-clockwise direction as viewed from
above.
z
Do not use thinner, benzene, gasoline, alcohol or other organic solvents. This may
degrade the materials.
Turn off the power switch. (See “7-6-1 Turning the Power Switch On” on page 39.)
Remove the side tower assembly. (See “8B-4-4 (1) Removing and Installing the Side Tower
Assembly” on page 145.)
Remove any pucks from inside the L and S buckets.
S bucket
S hopper disk
L hopper disk
L bucket
Wipe away any dirt from the puck paths using a soft cloth moistened with water or a neutral
cleanser diluted with water and then
fi
rmly wrung out.
* Use a cotton swab to clean narrow parts.
Wipe dry using a soft cloth so that no water or detergent remains, and then allow to dry completely.
To install, perform the procedure in reverse.
M259_08B_ENin6.indd 112
M259_08B_ENin6.indd 112
2/5/2013 8:11:44 AM
2/5/2013 8:11:44 AM