8B. Service
- Must be performed by a technician -
8B-3-7 Slider
Assembly
Symptom
Main cause
Action
Reference
page
Mini pucks are not supplied
during game play.
Normal Hockey Mode was selected
at the start of the game.
Select Big Bang Mode at the start of
the game.
Page 40
The machine is set to operate in
Normal Hockey Mode only.
Change the setting to “OFF”.
Page 67
There are not enough pucks.
Add spare pucks to the hopper.
Page 105
One or more deformed pucks is
mixed into the pucks.
Remove any deformed pucks, and
replace with spare pucks.
Page 105
The stopper base is not installed
correctly.
Install the stopper base correctly.
Page 161
Stopper solenoid malfunction.
Replace the stopper solenoid.
Page 161
Main PC board malfunction.
Replace the main PC board.
Page 146
Switching regulator (24V)
malfunction.
Replace the switching regulator
(24V).
Page 148
S (mini) pucks stack and
become jammed.
The cover panel is not installed
correctly.
Install the cover panel correctly.
Page 116
The illuminator assembly is not
installed correctly.
Install the illuminator assembly
correctly.
Page 170
8B-3-8 S
Escalator
Assembly
Symptom
Main cause
Action
Reference
page
Pucks remain inside the joint
rail cover.
S divider outlet sensor malfunction.
Replace the S divider outlet sensor.
Page 164
8B-3-9 L Escalator assembly
Symptom
Main cause
Action
Reference
page
Multiple big pucks are
supplied at once.
The L rail (H) cover is not installed
correctly.
Install the L rail (H) cover correctly.
Page 122
L divider outlet sensor malfunction.
Replace the L divider outlet sensor.
Page 167
L divider solenoid does not
operate.
A foreign object has entered the L
escalator assembly.
Remove the L rail (H) cover, and
remove the foreign object.
Page 122
L divider solenoid malfunction.
Replace the L divider solenoid.
Page 165
Switching regulator (24V)
malfunction.
Replace the switching regulator
(24V).
Page 148