Viper TX – Operation Instructions
24
AP-75710, Rev. 1.1, 09/01/2008
3.2 CHOOSING A PLACE FOR THE PRINTER
Choose a place for printer installation following the requirements in the table below.
Floor loading Capacity
2940Pa (300kg/m²) or over
Printer Winding System
Voltage
AC 220-240V
AC 100-120V / AC 220-240V
Frequency
50Hz
±
1Hz 60Hz,
50Hz
±
1Hz
Electrical
specifications
and
requirements
Capacity 1320
W
31,2 W
Recommended
printing
conditions
Temperature: 18°C to 30°C
Humidity: 35% - 80%, without condensation
Operational
conditions
Temperature: 10°C to 35°C
Humidity: 20% to 80%, without condensation
Rate of change Temperature: No more than 2°C per hour
Humidity: No more than 5% per hour
Environmental
Conditions
Storage and
transport
conditions
Temperature: -20°C to 40°C
Humidity: 20 to 85% with cleaning liquid in ink tubes and without
condensation.
Required space
12.7m² (144ft²) or larger.
Frontage of 4.7m (15.7ft)
or greater.
For 65” model
14.3m² (162ft²) or larger.
Frontage of 5.3m (17.7ft)
or greater.
For 90” model
Viper TX 65”
Length 3069
mm
Width 720
mm
Height 1221
mm
Viper TX 90”
Length 3639
mm
Width 720
mm
Height 1221
mm
Notes
•
Avoid the following temperature and humidity conditions. Otherwise, printed images may appear
differently from what you expect:
o
Places where sudden changes in temperature and humidity are expected, even though the
condition is within the range written above.
o
Places where direct sunlight or excessive lighting are experienced.
o
Places where air conditioners blow directly.
•
MUTOH recommends that the printer should be installed where air conditioning can be adjusted
easily.
Notes
•
Please note that some inks require a humidity of more than 50%, other inks can be used at 30%
humidity. Please contact your ink supplier for optimum printing conditions.
Downloaded From ManualsPrinter.com Manuals