Note:
See figure (a).
3.
Unlock hand pump: Hold sleeve (2). Turn han-
dle (1) counterclockwise until sleeve can be
moved back (arrow).
Note:
• See figure (b).
• After pulling the handle, wait briefly until
the chamber is optimally filled.
4.
Operate pump with handle (1) until bubble-
free fuel emerges from threaded vent plug.
5.
Close threaded vent plug.
6.
Continue to operate the pump until resist-
ance is noticeable (at least 50 times), to ach-
ieve full filling height.
Note:
See figure (c).
7.
Lock hand pump: Slide sleeve (2) forwards
and hold. Turn handle (1) clockwise until both
parts are firmly screwed together by hand.
8.
Remove hose from vent valve.
9.
Verify that fuel hand pump is locked: Han-
dle (1) must be tightened finger-tight.
226 | Fuel System | MS15065/01E 2019-01
TIM-ID: 0000064070 - 004