6.2 Putting into operation after scheduled out-of-service-period
Preconditions
☑
Engine is stopped and starting disabled.
Putting into operation/Commissioning
Item
Action
Lube oil system
Check engine oil level (→ Page 271).
Coolant circuit
Check engine coolant level (→ Page 280).
Check intercooler coolant level (→ Page 304).
Coolant circuit
Heat engine coolant with coolant preheater.
Fuel prefilter
Drain water (→ Page 233), (→ Page 235).
Monitoring system
Carry out lamp test (see manufacturer's documentation).
Engine/generator control
system
Switch on.
Select operating mode, e.g.: MANUAL, AUTOMATIC OPERATION.
Exhaust gas aftertreatment
system
Check RA dosing system for leaks.
Check gasket on dosing unit for gas-tightness.
Check electrical plug connections on the DCM and reducing agent compo-
nents (→ Page 90).
Throttle flap
Initiate teach-in routine (→ Page 248).
112 | Operation | MS15065/01E 2019-01
TIM-ID: 0000076668 - 002