793 – AL L2 P-Charge Air B
Cause
Corrective action
The charge-air pressure at sensor
B10.2 has violated limit value 2.
The charge-air pressure is too
high.
1. Reduce power.
2. Check sensor B10.11, replace as necessary.
3. Contact Service.
800 – AL L1 T-Exh. after Engine
Cause
Corrective action
The exhaust gas temperature
before DOC at sensor B4.33 has
violated limit value 1. The exhaust
gas temperature is too high.
1. Reduce power.
2. Contact Service.
833 – AL Emission Warning
Cause
Corrective action
Emission fault summary alarm
1. Check for additional messages.
2. Contact Service.
838 – AL ash volume
Cause
Corrective action
The ash volume determined from
the differential pressure through
the DPF following complete
regeneration compared with the
differential pressure of a new DPF
has violated the upper limit. Ash
loading is too high.
u
Contact Service.
843 – SD T-Charge Air before EGR
Cause
Corrective action
The signal from the charge-air
temperature sensor (B9) is faulty
of missing.
1. Check engine cabling (→ Page 321).
2. Check engine cabling (→ Page 321).
3. Contact Service.
4. Contact Service.
844 – AL HI T-Charge Air before EGR
Cause
Corrective action
The charge-air temperature at
sensor B9 has violated limit value
1. The charge-air temperature is
too high.
u
Check sensor.
MS15065/01E 2019-01
| Troubleshooting | 149
TIM-ID: 0000078552 - 003