7. APPLICATION INSTRUCTIONS
7
−
93
MELSEC-A
Program Examples LRDP
A program to store data of D3 to D8 of the 3rd local station in D99 to D104 of the
master station when X3 is ON.
*1: The contact which corresponds to M1 shown in the program example should be converted into a
pulse. If a pulse is not used, following execution of the LRDP instruction will be disabled.
*2: The contact which corresponds to M0 shown in the program example should be turned ON by the
SET instruction. If the OUT or PLS instruction is used, the LRDP instruction may often be executed
incorrectly.
•
Coding
0 LD
X003
1 PLS
M1
4 LD
M1
5 SET
M0
6 LD
M0
7 MPS
8 ANI
M9200
9 ANI
M9201
10
ANI
M9202
11
ANI
M9203
12
LRDP
K3
D3
D99
K6
23
MPP
24
AND
M9201
25
RST
M0
26
RST
M9200
29
RST
M9201
32
END
Use a pulse signal for
this command. (*1)
Provide interlock using
the LRDP instruction
execution flag.
If the LWTP instruction is used to the same station,
provide interlock using the LWTP instruction execution flag.
Turned OFF by the
sequence program.
Turned OFF by the
sequence program.
Turned ON by
the PC CPU.
Executed only once.
Executed only once.
M9200
M9201
M0
M1
X3
LRDP
OFF
OFF
OFF
OFF
ON
ON
ON
X003
M1
M0 M9200
M9201
M9202 M9203
PLS
M1
K
K
LRDP 3
D3 D99
6
M9201
SET M0
RST
M0
RST M9200
RST M9201
(*2)
When X3 is ON, M0 turns ON.
If the LRDP and LWTP instructions are not being
executed when M0 is ON, the LRDP instruction
for the 3rd station is executed, and M9200 is
turned ON.
At read completion, M0, M9200 and M9201 are
turned OFF.
0
4
6