7. APPLICATION INSTRUCTIONS
7
−
128
MELSEC-A
(8) Error codes stored in (D2) by the CHK instruction vary with conditions
establish-ed as shown below.
Condition established
Condition Nos. 1 to 50
Condition Nos. 51 to 100
Condition Nos. 101 to 150
Condition No. 1
(data of error code No. 1)
100+ {2
×
(contact No.) -1
400+ {2
×
(contact No.) -1
700+ {2
×
(contact No.) -1
Condition No. 2
(data of error code No. 2)
101+ {2
×
(contact No.) -1
401+ {2
×
(contact No.) -1
701+ {2
×
(contact No.) -1
Condition No. 3
(data of error code No. 3)
200+ {2
×
(contact No.) -1
500+ {2
×
(contact No.) -1
800+ {2
×
(contact No.) -1
Condition No. 4
(data of error code No. 4)
201+ {2
×
(contact No.) -1
501+ {2
×
(contact No.) -1
801+ {2
×
(contact No.) -1
Condition No. 5
(data of error code No. 5)
301+ {2
×
(contact No.) -1
601+ {2
×
(contact No.) -1
901+ {2
×
(contact No.) -1
Condition No. 6
(data of error code No. 6)
300+ {2
×
(contact No.) -1
600+ {2
×
(contact No.) -1
900+ {2
×
(contact No.) -1
REMARK
Error code numbers displayed after the CHK instruction execution indicate kind of the error
occurred. Prepare a troubleshooting table corresponding to the system for quick remedies.
Refer to (2) for conditions.
Error code
No.
Cause Corrective
action
301
Conveyor 1: Backward run occurred
when the forward stroke end sensor
•
Check limit switch X1.
•
Check the conveyor.
X
X
X
X
X
X
Contact
No. 1
Contact
No. 50
Contact
No. 51
Contact
No. 100
Contact
No. 101
Contact
No. 150
CHK (D1) (D2)
P254