7. APPLICATION INSTRUCTIONS
7
−
147
MELSEC-A
Program Examples DSFLP
(1) A program to change present position data of axis 2 to the BCD data set at X90
to XAF when X81 is turned ON.
•
Coding
24
LD
X081
25
PLS
M11
28
LD
M11
29
SET
M10
30
LD
M10
31
ANI
M2002
32
DBINP
K8X090
D966
41
DSFLP D2
K0
48
RST
M10
49
END
The present position data change storage flag
(M10) is set when X81 is turned ON.
When axis 2 is not started, the BCD data of X90
to XAF are stored in D966 and D967 (present
position data change registers).
The DSFLP instruction is executed.
The present position data change storage flag is
reset.
24
28
30
X081
PLS
M11
M11
SET
M10
M10 M2002
P K8
DBIN
X090
D966
P
K
DSFL
D2
0
RST
M10
Summary of Contents for MELSEC-A series