2-13
2-13
502809
502809
CHAPTER 2 TROUBLESHOOTING FOR CONTROL CIRCUITS
CHAPTER 2 TROUBLESHOOTING FOR CONTROL CIRCUITS
(13) Secure harness if loose
(13) Secure harness if loose
Replace inverter if wire breaks
Replace inverter if wire breaks
(11) Remove right traction inverter DSP card cover, then
(11) Remove right traction inverter DSP card cover, then
check flat cable
check flat cable
looseness or w
looseness or w
ire breakage
ire breakage
Normal
Abnormal
Normal
Abnormal
Continuity
Continuity
No
No
continuity
continuity
(12) Dis
(12) Dis
conn
conn
ect connec
ect connec
tor
tor
E-0
E-0
7
7
of right
of right
traction inver
traction inver
ter
ter
Check continuity between E-01-3 and E-07-17(10)
Check continuity between E-01-3 and E-07-17(10)
Check continuity between E-01-6 and E-07-20(12)
Check continuity between E-01-6 and E-07-20(12)
Power supply
Power supply
(14) Dis
(14) Dis
conne
conne
ct connec
ct connec
tor E-02
tor E-02
of logic unit
of logic unit
Check continuity between E-02-5 and E-07-3(3)
Check continuity between E-02-5 and E-07-3(3)
Check continuity between E-02-6 and E-07-4(4)
Check continuity between E-02-6 and E-07-4(4)
Continuity
Continuity
No
No
continuity
continuity
(17) Measure voltage between E-07-18(11) and
(17) Measure voltage between E-07-18(11) and
E-07-20(12)
E-07-20(12)
Confirm v
Confirm v
alue is
alue is
8 ±
8 ±
2V
2V
Normal
Abnormal
Normal
Abnormal
(
(
15
15
) C
) C
on
on
ne
ne
c
c
t co
t co
nn
nn
ec
ec
to
to
r E
r E
-0
-0
1,
1,
th
th
en
en
tu
tu
r
r
n o
n o
n p
n p
ow
ow
er
er
ag
ag
ai
ai
n
n
(
(
16
16
) R
) R
ep
ep
ai
ai
r o
r o
r r
r r
ep
ep
la
la
c
c
e h
e h
ar
ar
ne
ne
s
s
s
s
(18) Disconnect battery plug
(18) Disconnect battery plug
(20) Replace power supply card of logic unit
(20) Replace power supply card of logic unit
(19) Ensure all connectors are connected.
(19) Ensure all connectors are connected.
Then turn on power again
Then turn on power again
"
"
E
E
5
5
"
"
N
N
o
o
t
t
"
"
E
E
5
5
"
"
(21) D
(21) D
isc
isc
onnec
onnec
t batt
t batt
ery
ery
plug, then per
plug, then per
form
form
Inverter
Inverter
disc
disc
harging
harging
wor
wor
k
k
(22) Replace DSP card of
(22) Replace DSP card of
right traction inverter
right traction inverter
(24) Disconnect battery plug, then perform inverter
(24) Disconnect battery plug, then perform inverter
discharging work
discharging work
(25) Replace right traction inverter
(25) Replace right traction inverter
(DSP card is normal)
(DSP card is normal)
CAN
CAN
If fault remains
If fault remains
(23) Connect connector
(23) Connect connector
securely
securely
Thermal
Thermal
Summary of Contents for FB13PNT
Page 2: ......
Page 12: ......
Page 86: ...1 73 1 73 Fig 5 Fig 5 500969 500969...
Page 264: ...4 13 4 13...
Page 266: ...5 1 5 1...
Page 267: ...5 2 5 2...
Page 268: ...5 3 5 3...
Page 269: ...5 4 5 4...
Page 270: ...5 5 5 5...
Page 271: ...5 6 5 6...
Page 272: ...5 7 5 7...
Page 273: ...5 8 5 8...
Page 274: ...5 9 5 9...
Page 275: ...5 10 5 10...
Page 276: ...5 11 5 11...
Page 277: ...5 12 5 12...
Page 278: ...5 13 5 13...
Page 279: ...5 14 5 14...
Page 280: ...5 15 5 15...
Page 281: ...5 16 5 16...
Page 282: ...5 17 5 17...
Page 283: ...5 18 5 18...
Page 284: ...5 19 5 19...
Page 285: ...5 20 5 20...
Page 286: ...5 21 5 21...
Page 287: ...5 22 5 22...
Page 288: ...5 23 5 23...
Page 289: ...5 24 5 24...
Page 290: ...5 25 5 25...