1-37
1-37
CHAPTER 1 CONTROLLER
CHAPTER 1 CONTROLLER
5.
5.7
7
Se
Settu
up
p O
Op
pti
tion
ons
s (G
(Gro
rou
up
p 3)
3)
Option
Option
#
#
T
Tiittlle
e
o
of
f
O
Op
pttiio
on
n
D
De
essccrriip
pttiio
on
n
R
Ra
an
ng
ge
e
Default
Default
Value
Value
#
#4
40
0
T
Trru
ucck
k T
Tyyp
pe
e
This option is u
This option is used to set
sed to set the type of
the type of
the truck.
the truck.
0: 3-Wheel model
0: 3-Wheel model
1: 4-Wheel model
1: 4-Wheel model
–
–
#
#4
41
1
B
Baatttte
erry V
y Vo
ollttaag
ge
e
This option
This option is used
is used to set
to set the voltag
the voltage
e
of the battery.
of the battery.
3
36
6,
,
4
48
8
[[V
V]]
–
–
#
#4
42
2
B
Baatttte
erry
y T
Tyyp
pe
e
This option is u
This option is used to set
sed to set the type of
the type of
the battery.
the battery.
The electric d
The electric discharge charact
ischarge characteristic
eristic
of a battery changes with
of a battery changes with battery
battery
type.
type.
0: Normal BDI
0: Normal BDI
1: Tubular BDI
1: Tubular BDI
2: Gel BDI
2: Gel BDI
–
–
#43
#43
Hydraulic Control
Hydraulic Control
Selection
Selection
This option is u
This option is used to set
sed to set the type of
the type of
the hydraulic control
the hydraulic control
0: FC specification
0: FC specification
1: MC specification
1: MC specification
–
–
#
#4
44
4
M
Maasst
t T
Tyyp
pe
e
This option is u
This option is used to set
sed to set the type of
the type of
the mast.
the mast.
2FF: 2-stage full-free
2FF: 2-stage full-free
3FF: 3-stage full-free
3FF: 3-stage full-free
2SP: 2-stage panorama
2SP: 2-stage panorama
–
–
#
#4
45
5
V
Vaallvve
e S
Se
eccttiio
on
n
This option is used
This option is used to set the
to set the
number of valve sections.
number of valve sections.
1: 3 ways (lift, tilt, attachment 1)
1: 3 ways (lift, tilt, attachment 1)
2: 4 ways (lift, tilt, attachment 1,2)
2: 4 ways (lift, tilt, attachment 1,2)
–
–
#46
#46
Battery Voltage
Battery Voltage
Adjustment
Adjustment
This setting corr
This setting corrects the gap
ects the gap of the
of the
battery voltage which the controller
battery voltage which the controller
recognizes, and actual battery
recognizes, and actual battery
voltage.
voltage.
Measure actual battery voltage and
Measure actual battery voltage and
operate the direction lever in
operate the direction lever in order
order
to adjust the value which is shown
to adjust the value which is shown
on the service tool actual battery
on the service tool actual battery
voltage.
voltage.
5
5..0
0
tto
o
1
12
20
0..0
0
[[V
V]]
–
–
#
#4
47
7
FFo
oo
ot
t D
Diirre
eccttiio
on
n
This option is used t
This option is used to enable the
o enable the
function for foot direction option.
function for foot direction option.
Armrest FNR
Armrest FNR
1: Standard direction lever
1: Standard direction lever
2: Foot Directional Control
2: Foot Directional Control (FoDiCo)
(FoDiCo)
3: Armrest FNR
3: Armrest FNR
–
–
#
#4
48
8
LLo
oaad
d M
Me
ette
er
r FFu
un
nccttiio
on
n
This option
This option is used
is used to enable
to enable/disable
/disable
the load meter.
the load meter.
0: Disable
0: Disable
1: Enable
1: Enable
#
#5
50
0
T
Tiillt H
t Ho
orriizzo
on F
n Fu
unc
ncttiio
on
n
This option
This option is used
is used to enable
to enable/disable
/disable
the tilt horizon function.
the tilt horizon function.
0: Disable
0: Disable
1: Enable
1: Enable
#5
#51
1
T
Til
ilt
t Ho
Horriz
izo
on
n Ad
Adju
just
stm
me
ent
nt
When the #50 “Tilt horizon function “
When the #50 “Tilt horizon function “
is enabled, this option is used to
is enabled, this option is used to
store the analog value when the
store the analog value when the
mast is positioned horizontally.
mast is positioned horizontally.
0 to 255
0 to 255
#
#5
55
5
LLo
oaad A
d Ad
djju
ussttm
me
en
ntt
When the #48 “Load
When the #48 “Load Meter” is
Meter” is
enabled, this option is used to store
enabled, this option is used to store
the analog value when the live load
the analog value when the live load
is zero.
is zero.
0 to 255
0 to 255
Note:
Note:
(1)
(1) The data of a g
The data of a group 3 has no defa
roup 3 has no default value, but it nee
ult value, but it needs to set data
ds to set data by the actual tru
by the actual truck type. If the value
ck type. If the value and the truck
and the truck model
model
aren’t in agreement, the truck does not operate normally.
aren’t in agreement, the truck does not operate normally.
(2)
(2) When you set up
When you set up for the first
for the first time, set up th
time, set up the group 3 fir
e group 3 first, and then set
st, and then set default data of g
default data of group 1 and 2.
roup 1 and 2.
(3)
(3) If SUO d
If SUO data is not s
ata is not set, th
et, the erro
e error code “
r code “62” is disp
62” is displayed
layed..
(4)
(4) This value was adju
This value was adjusted at the tim
sted at the time of LOGIC
e of LOGIC CARD inspection. Adju
CARD inspection. Adjust the value if t
st the value if the value shown on
he value shown on the service t
the service tool is
ool is
different from actual battery voltage.
different from actual battery voltage.
Summary of Contents for FB13PNT
Page 2: ......
Page 12: ......
Page 86: ...1 73 1 73 Fig 5 Fig 5 500969 500969...
Page 264: ...4 13 4 13...
Page 266: ...5 1 5 1...
Page 267: ...5 2 5 2...
Page 268: ...5 3 5 3...
Page 269: ...5 4 5 4...
Page 270: ...5 5 5 5...
Page 271: ...5 6 5 6...
Page 272: ...5 7 5 7...
Page 273: ...5 8 5 8...
Page 274: ...5 9 5 9...
Page 275: ...5 10 5 10...
Page 276: ...5 11 5 11...
Page 277: ...5 12 5 12...
Page 278: ...5 13 5 13...
Page 279: ...5 14 5 14...
Page 280: ...5 15 5 15...
Page 281: ...5 16 5 16...
Page 282: ...5 17 5 17...
Page 283: ...5 18 5 18...
Page 284: ...5 19 5 19...
Page 285: ...5 20 5 20...
Page 286: ...5 21 5 21...
Page 287: ...5 22 5 22...
Page 288: ...5 23 5 23...
Page 289: ...5 24 5 24...
Page 290: ...5 25 5 25...