A953 HANDY GOT
Specifications 4
4-5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A
4.2
PLC CPU which can be monitored
Whether or not a PLC CPU can be monitored in the Handy GOT is determined by the system
(connection form) up to the monitored PLC CPU.
4.2.1
In case of A953 Handy GOT
The table below shows the PLC CPU of each connection form which can be monitored.
(The A953 Handy GOT can be connected to a PLC equipped with the RS-232C interface.)
Connectable PLC list
*1 When the AnNCPU (S1), the A2SCPU, the A0J2HCPU or the A2CCPU is monitored, data
cannot be written to the CPU whose version is former than the following version.
AnNCPU (S1): version L (with link), version H (without link)
A2SCPU: version H
A0J2HCPU: version E
A2CCPU: version H
*2 Computer link connection is not available in the A2CCPU.
*3 When connecting a computer link unit to the A2SCPU, the A2SHCPU-S1, the A2SHCPU,
the A1SHCPU, the A1SJHCPU, the A0J2HCPU, the A171SHCPU or the A172SHCPU, use
the computer link unit software version U or later.
The A0J2-C214-S1 (computer link unit dedicated to the A0J2HCPU) is not available.
*4 The FX
1S
/FX
1N
/FX
2N
/FX
2NC
Series PLC can be connected by way of a expansion board for
RS-232C communication or communication adapter.
PLC CPU which can be monitored
CPU direct
connection
Reference
Computer link
connection
Reference
QCPU (Q mode)
✓
Chapter 6
✓
Chapter 7
QCPU (A mode)
✓
Chapter 6
✓
Chapter 7
QnACPU
✗
−
✓
Chapter 7
ACPU
Except A1FXCPU
✗
−
▲
*1*2*3
Chapter 7
A1FXCPU
✗
−
✗
−
FXCPU
✓
*4
✗
−
FA controller
✗
−
✗
−
Motion controller CPU
✗
−
✓
*3
Chapter 7
PLC by Omron
✗
−
✓
Chapter 8
PLC by Yaskawa Electric
✗
−
✓
Chapter 9
PLC by Allen-Bradley
✓
Chapter 10
✗
−
PLC by Sharp
✓
Chapter 11
✗
−
Microcomputer board
✓
Chapter 12
✗
−
PLC by Siemens
✓
Chapter 13
✗
−
PLC by Toshiba
✗
−
✗
−
Summary of Contents for A953GOT-LBD-M3-H
Page 4: ...A953 HANDY GOT ii ...
Page 6: ...A953 HANDY GOT iv ...
Page 14: ...A953 HANDY GOT xii MEMO ...
Page 28: ...A953 HANDY GOT Introduction 1 1 8 MEMO ...
Page 42: ...A953 HANDY GOT Installation Wiring 2 2 14 MEMO ...
Page 58: ...A953 HANDY GOT Wiring and Handling of Switches 3 3 16 MEMO ...
Page 72: ...A953 HANDY GOT Specifications 4 4 14 MEMO ...
Page 80: ...A953 HANDY GOT CPU Direct Connection 6 6 6 MEMO ...
Page 98: ...A953 HANDY GOT Connection to PLC by Omron 8 8 10 MEMO ...
Page 104: ...A953 HANDY GOT Connection to PLC by Yaskawa Electric 9 9 6 MEMO ...
Page 108: ...A953 HANDY GOT Connection to PLC by Allen Bradley 10 10 4 MEMO ...
Page 130: ...A953 HANDY GOT Connection to PLC by Siemens 13 13 4 MEMO ...
Page 134: ...A953 HANDY GOT Diagnostics 14 14 4 MEMO ...