A953 HANDY GOT
Connection to Microcomputer 12
12-2
12.2
Transmission specifications
The table below shows the transmission specifications for communication between the GOT
and the host.
12.3
Connection cable
12.3.1
When DTR is used
1) Connection diagram
Note: Write the "Pin number" column on the host side in accordance with the specifications
of the connected host.
2) Used connectors and connector covers
-
Connector on the side of the cable dedicated to the GOT
The connector of the cable dedicated to the GOT (F9GT-HCAB-
M) has the following
model name. Use a counterpart connector compatible with this connector.
17JE-23250-02 (D8A2)
25-pin D-Sub, male connector manufactured by DDK Ltd. (DDK)
The cable dedicated to the GOT (F9GT-HCAB1-
M) is the untied wire type.
-
Port on the host side
Use a connector compatible with the used host.
Item
Contents of setting
Data bit
7 bits
Parity bit
Provided (even)
Stop bit
1 bit
Sum check
Provided
Transmission speed
4,800, 9,600 or 19,200 bps (default: 19,200 bps)
GOT side (F9GT-HCAB
-3M)
(
= none or 1)
Cable connection and signal direction
Host
Signal
name
Untied
wire color
Pin
number
Pin
number
Signal
name
CD(DCD)
Blue
8
FG
RD(RXD)
Red
4
SD(TXD)
SD(TXD)
Black
2
RD(RXD)
ER(DTR)
White
3
RS(RTS)
SG(GND)
Orange
10
CS(CTS)
DR(DSR)
Green
5
5V
RS(RTS)
Yellow
6
DR(DSR)
CS(CTS)
Brown
7
ER(DTR)
FG
(SHIELD)
Drain wire
1
SG(GND)
Class D grounding
Summary of Contents for A953GOT-LBD-M3-H
Page 4: ...A953 HANDY GOT ii ...
Page 6: ...A953 HANDY GOT iv ...
Page 14: ...A953 HANDY GOT xii MEMO ...
Page 28: ...A953 HANDY GOT Introduction 1 1 8 MEMO ...
Page 42: ...A953 HANDY GOT Installation Wiring 2 2 14 MEMO ...
Page 58: ...A953 HANDY GOT Wiring and Handling of Switches 3 3 16 MEMO ...
Page 72: ...A953 HANDY GOT Specifications 4 4 14 MEMO ...
Page 80: ...A953 HANDY GOT CPU Direct Connection 6 6 6 MEMO ...
Page 98: ...A953 HANDY GOT Connection to PLC by Omron 8 8 10 MEMO ...
Page 104: ...A953 HANDY GOT Connection to PLC by Yaskawa Electric 9 9 6 MEMO ...
Page 108: ...A953 HANDY GOT Connection to PLC by Allen Bradley 10 10 4 MEMO ...
Page 130: ...A953 HANDY GOT Connection to PLC by Siemens 13 13 4 MEMO ...
Page 134: ...A953 HANDY GOT Diagnostics 14 14 4 MEMO ...
Page 141: ......