7 - 17
7 SYNCHRONOUS CONTROL
(3) [Pr.420] Auxiliary shaft gear: Numerator (150n,
150n), [Pr.421] Auxiliary shaft gear: Denominator
(150n, 150n)
Set the numerator and the denominator for auxiliary shaft gear to convert the
input value. The input value is converted as follows.
Input value after conversion = Input value before conversion
Auxiliary shaft gear: Numerator
Auxiliary shaft gear: Denominator
The input value direction can be reversed by setting a negative value in the
numerator of the auxiliary shaft gear.
Set the denominator of the auxiliary shaft gear to a value within the range from 1
to 2147483647.