8 - 13
8 AUXILIARY AND APPLIED FUNCTIONS
REMARK
"The last synchronous control session" indicates status just before the last
synchronous control session was stopped as follows. These are listed with the last
synchronization status.
• Just before [Rq.380] Synchronous control start (n) turns from ON to OFF.
• Just before deceleration stop by a stop command or an error, etc.
• Just before the Multiple CPU system power supply turned OFF.
(2) Current value per cycle after main shaft gear, current value per
cycle after auxiliary shaft gear when starting synchronous control
The current value per cycle after main shaft gear/current value per cycle after
auxiliary shaft gear is restored as follows according to the main input
axis/auxiliary shaft operation executed before starting synchronous control.
Servo input axis
Synchronous encoder axis
Operation of main input axis
(Before synchronous control
start)
Absolute position
detection system
valid
Absolute position
detection system
invalid
Command
generation axis
Incremental
synchronous
encoder
Absolute
synchronous
encoder
Synchronous
encoder via
device
Home position return
Restoration method 1)
—
—
Current value change
Restoration method 1)
Restoration
method 1)
Restoration method 1)
Speed control ( )
(Note-1)
Restoration method 1)
Restoration
method 1)
—
Fixed-pitch feed control
Restoration method 1)
Restoration
method 1)
—
Speed/position switching
control
(Note-2)
Restoration method 1)
—
—
Connection to servo amplifier
Restoration
method 2)
Restoration
method 1)
— —
Connection to synchronous
encoder
— —
Restoration
method 1)
Restoration method 2)
Others
Restoration method 2)
Restoration
method 2)
Restoration method 2)
(Note-1): When it starts by turning OFF the feed current value update command (M3212+20n) or [Rq.347]
Feed current value update request command (20n).
(Note-2): When it starts by turning OFF the feed current value update command (M3212+20n).
(a) Restoration method 1)
The new value of the current value per cycle after main shaft gear/current
value per cycle after auxiliary shaft gear is calculated based on the current
value after composite main shaft gear/auxiliary shaft current value.
[Main shaft]
Current value per cycle
after main shaft gear
= Main shaft gear ratio
Current value after
composite main shaft gear
[Auxiliary shaft]
Current value per cycle
after auxiliary shaft gear
=
Auxiliary shaft gear
ratio
Auxiliary shaft current value