7 - 25
7 SYNCHRONOUS CONTROL
(9) [Pr.430] Slippage amount at auxiliary shaft clutch ON
(150n, 150n)
Set the slippage amount at clutch ON when the slippage method is set in [Pr.428]
Auxiliary shaft clutch smoothing method (150n).
The slippage amount is set in units based on the current value selected in
[Pr.423] Auxiliary shaft clutch reference address setting (150n).
If the set amount is negative, the slippage amount at clutch ON is controlled as 0
(direct).
(10) [Pr.431] Slippage amount at auxiliary shaft clutch OFF
(150n, 150n)
Set the slippage amount at clutch OFF when the slippage method is set in
[Pr.428] Auxiliary shaft clutch smoothing method (150n).
The slippage amount is set in units based on the current value selected in
[Pr.423] Auxiliary shaft clutch reference address setting (150n).
If the set amount is negative, the slippage amount at clutch OFF is controlled as
0 (direct).