8 - 7
8 AUXILIARY AND APPLIED FUNCTIONS
(e) Values of [Md.407] Cam axis current value per cycle (30n,
30n), [Md.408] Cam reference position (30n,
30n), and [Md.409] Cam axis current feed value (30n,
30n) during speed-torque control are based on the command from
the input axis. It is not based on the actual output axis position.
[Md.407] Cam axis current value per cycle (30n, 30n),
[Md.408] Cam reference position (30n, 30n), and
[Md.409] Cam axis current feed value (30n, 30n) are
restored based on the actual output axis position at the position control
mode switching.
(f) Phase compensation is valid during speed-torque control.
(g) Switching to speed control mode, torque control mode, or continuous
operation to torque control mode during synchronous control is not reflected
on the scroll monitor.
(h) During synchronous control start analysis or during the synchronous control
stop due to [Rq.380] Synchronous control start (n) ON to OFF or
stop factor occurrence, the control mode switching request is ignored. Take
[Rq.380] Synchronous control start (n) in an interlock.
(i) The synchronous control change function cannot be used during speed-
torque control.
(2) Precautions at control mode switching
(a) When using continuous operation to torque control mode, use the servo
amplifiers that are compatible with continuous operation to torque control. If
servo amplifiers that are not compatible with continuous operation to torque
control are used, a minor error (error code: 318) will occur at request of
switching to continuous operation to torque control mode.
Summary of Contents for Q172DSCPU
Page 1: ......
Page 19: ...A 18 MEMO ...
Page 39: ...3 4 3 SYNCHRONOUS CONTROL MODULE MEMO ...
Page 129: ...5 50 5 INPUT AXIS MODULE MEMO ...
Page 199: ...7 60 7 SYNCHRONOUS CONTROL MEMO ...
Page 310: ......
Page 311: ......