8 - 22
8 AUXILIARY AND APPLIED FUNCTIONS
4) The search fails.
Cam axis current value per cycle
Cam axis current feed value
(Current feed value)
Cam reference position
Restoration fails. No match
is found for the current
feed value within1 cycle.
(b) With a feed operation cam pattern
1) Search from "Cam axis current value per cycle = 0".
(Cam data starting point = 0)
Search from "Cam axis
current value per cycle=0".
Cam axis current value per cycle
Cam axis current feed value
(Current feed value)
Cam reference position
Restore to the first current
feed value that matches.
(Other values are not restored.)
2) Search from a value in the middle of the cam axis current value per
cycle. (Cam data starting point = 0)
Cam axis current value per cycle
[Pr.468] Cam axis current value per cycle
(Initial setting)
(150n, 150n)
Cam axis current feed value
(Current feed value)
New cam reference position
Cam reference position
at starting the restoration
Update the cam reference
position in the next cycle
automatically.
Restore to the first
current feed value
that matches.