5 - 18
5 INPUT AXIS MODULE
(1) [Rq.341] Command generation axis stop command (20n)
This command is a signal which stop a starting command generation axis from
an external source and becomes effective at leading edge of signal.(A command
generation axis for which the stop command is turning on cannot be started.)
The operation at stop command input is the same as the stop command
(M3200+20n) of each axis.
Refer to the "Q173D(S)CPU/Q172D(S)CPU Motion controller (SV13/SV22)
Programming Manual (REAL MODE)" for details of stop command (M3200+20n).
(2) [Rq.342] Command generation axis rapid stop command
(20n)
This command stops a starting command generation axis rapidly from an
external source and becomes effective at leading edge of signal. (A command
generation axis for which the rapid stop command is turning on cannot be
started.)
The operation at rapid stop command input is the same as the rapid stop
command (M3201+20n) of each axis.
Refer to the "Q173D(S)CPU/Q172D(S)CPU Motion controller (SV13/SV22)
Programming Manual (REAL MODE)" for details of rapid stop command
(M3201+20n).
(3) [Rq.343] Command generation axis forward rotation JOG start
command (20n)
JOG operation to the address increase direction is executed while [Rq.343]
Command generation axis forward rotation JOG start command (20n)
is turning on.
When 20n is turned off, a deceleration stop is executed in the
deceleration time set in the parameter block.
The operation at forward rotation JOG start command input is the same as the
forward rotation JOG start command (M3202+20n) of each axis.
Refer to the "Q173D(S)CPU/Q172D(S)CPU Motion controller (SV13/SV22)
Programming Manual (REAL MODE)" for details of forward rotation JOG start
command (M3202+20n).
(4) [Rq.344] Command generation axis reverse rotation JOG start
command (20n)
JOG operation to the address decrease direction is executed while [Rq.344]
Command generation axis reverse rotation JOG start command (20n)
is turning on.
When 20n is turned off, a deceleration stop is executed in the
deceleration time set in the parameter block.
The operation at reverse rotation JOG start command input is the same as the
reverse rotation JOG start command (M3203+20n) of each axis.
Refer to the "Q173D(S)CPU/Q172D(S)CPU Motion controller (SV13/SV22)
Programming Manual (REAL MODE)" for details of reverse rotation JOG start
command (M3203+20n).