![Mitsubishi Electric Q172DSCPU Programming Manual Download Page 152](http://html.mh-extra.com/html/mitsubishi-electric/q172dscpu/q172dscpu_programming-manual_1811840152.webp)
7 - 13
7 SYNCHRONOUS CONTROL
7.1.4 Main shaft clutch control data
Symbol
Setting item
Setting details
Setting value
Fetch cycle
Default
value
Device No.
Rq.400
Main shaft clutch
command
Set the clutch command
ON/OFF.
OFF : Main shaft clutch
command OFF
ON : Main shaft clutch
command ON
OFF 10n
Rq.401
Main shaft clutch
control invalid
command
Set the command disable the
clutch control temporarily.
OFF : Main shaft clutch
control valid
ON : Main shaft clutch
control invalid
OFF 10n
Rq.402
Main shaft clutch forced
OFF command
Set the command to force the
clutch OFF.
OFF : Main shaft clutch
normal control
ON : Main shaft clutch
forced OFF
Operation
cycle
OFF 10n
(1) [Rq.400] Main shaft clutch command (10n)
Use ON/OFF for the main shaft clutch command. This command is used with the
following settings.
• The clutch ON control mode is "1: Clutch command ON/OFF", "2: Clutch
command leading edge" or "3: Clutch command trailing edge".
• The clutch OFF control mode is either "2: Clutch command leading edge" or "3:
Clutch command trailing edge".
Status is considered as clutch command OFF just before starting synchronous
control. If synchronous control is started while the clutch command is ON, the
condition is established just after starting synchronous control, by setting "2:
Clutch command leading edge". The condition is not established just after
starting, by setting "3: Clutch command trailing edge".
(2) [Rq.401] Main shaft clutch control invalid command (10n)
The main shaft clutch control is invalid if ON is set. The previous clutch ON/OFF
status remains before clutch control becomes invalid.
Clutch control will not become invalid during movement by [Pr.408] and [Pr.410]
before clutch ON and clutch OFF. Instead, clutch control will become invalid after
movement is completed.
(3) [Rq.402] Main shaft clutch forced OFF command (10n)
Set ON to force the clutch OFF. The output value from the clutch becomes 0
immediately, even during clutch smoothing. The slippage (accumulative) amount
is set to 0 if smoothing with a slippage method.
Reset to OFF to restart the clutch control from the clutch OFF status after using
the clutch forced OFF command.